Abstract

Experimental results are reported on the assessment of steady and pulsed air jet vortex generators (AJVGs) for the suppression of dynamic stall on a sinusoidal pitching RAE9645 airfoil model. Tests at Rec of 1 million, at reduced pitching frequencies between 0.01 and 0.10 were performed with and without steady and pulsed AJVG blowing. The effect of jet momentum coefficient (0.0003< Cμ< 0.0046), jet duty cycle (0.25< DC< 1) and jet pulsing frequency (0.29< F+< 2.93) were investigated. Pulsed air jet blowing with F+ in the range 0.5–1.0 and with a duty cycle in the range 0.4–0.5, was found to be the most effective to achieve full suppression of dynamic stall vortex formation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.