Background Packed red blood cell (PRBC) units stored and unused at community hospitals are transferred to trauma centers near the end of their shelf storage life, because of a higher likelihood of utilization before expiration without consideration of coagulation system effects. This study was conducted to determine if the stored age of PRBC units has an effect on coagulation. Methods Single-donor citrate/phosphate/dextrose–preserved, PRBCs, and fresh frozen plasma (FFP) were recalcified in an in vitro model. The activated clotting time (ACT) was measured using the microsample method on days 3, 19, 20, and 33 from the date of donation. Results The ACT was prolonged as the age of PRBCs increased while other factors were held constant. ACTs on days 19, 20, and 33 were prolonged relative to day 3. Measurements taken on day 33 were significantly prolonged relative to day 20. Conclusions Increasing age of PRBCs measured from the date of donation adversely affects the global coagulation status. This study suggests that we should re-evaluate current blood banking and transfusion practices in trauma care.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.