Abstract
Abstract A novel injector has been designed and cold flow injection tests were performed in a modified supersonic wind tunnel. To complement these experimental studies three dimensional STAR-CCM+CFD simulations were developed. The pulse width may be varied, with options of injecting gas for 33 %, 50 % and 66 % of the injection period. The scramjet combustor environment is simulated in a supersonic wind tunnel through a backward facing step for secondary injection purposes and a 157.5 cm (62-inch) long test section. The gas in secondary injection is carbon dioxide and the primary flow is air. The simulations show a coupled interaction between the forcing from injection and the shear layer. Steady state static pressure measurements on the lower wall of the wind tunnel test section agree well with the simulated static pressure along the lower wall. The pulse width strongly impacts shear layer reattachment on the lower wall and varies between 2.4 and 4.3 step heights. Reduction in duty cycle from 66 % to 33 % at 1 kHz caused ~30 % reduction in the shear layer reattachments distance, which points to large scale mixing enhancement.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.