Abstract

In the work, on the example of a coating of a metal-ceramic alloy of 50 vol.% TiC / 50 vol.% (Ni-Cr) of the working part of a die for granulating plastics, the results of the study of the possibilities of using the pulsed electron-ion irradiation method to eliminate continuity gaps in the coating in the form microcracks formed during operation of the die through through the cross section. It has been shown that pulsed electron-ion irradiation makes it possible to restore the integrity of metal-ceramic coatings by filling cracks with a melt of a nickel-chrome binder metal-ceramic composition extending to the surface of the coating of cracks to a depth of more than 100 μm.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.