Abstract

Phase-distribution data have been generated for two-phase (air-water) flow splitting at an impacting tee junction with a horizontal inlet and inclined outlets. This investigation also considers the full-separation capabilities of the junction and the effect of the outlet angle of inclination on partial separation at various inlet conditions. A flow loop with the ability to incline the outlets from −90° downward to +90° upward was constructed. The operating conditions were as follows: test-section inside diameter of 13.5 mm, nominal junction pressure (Ps) of 200 kPa (abs), near ambient temperature (Ts), inlet superficial gas velocities (JG1) ranging from 2.0 to 40 m/s, inlet superficial liquid velocities (JL1) ranging from 0.01 to 0.18 m/s, mass split ratios (W3/W1) from 0 to1.0 and inlet flow regimes of stratified, wavy, and annular. The data reveal that the degree of maldistribution of the phases depended on the inlet conditions, the mass split ratio at the junction, and the inclination angle of the outlets.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.