Abstract

The results of experiments on municipal wastewater primary effluent are presented for a pilot-scale submerged membrane bioreactor (SMBR). The SMBR pilot plant employed an ultrafiltration membrane with a nominal pore size of 0.035 μm and was operated at a constant membrane flux of 30 L/m 2 h. The mixed liquor suspended solids (MLSS) concentration was maintained at 8±2 g/L and steady-state fouling rates were determined for 10, 5, 4, 3, and 2-d MCRTs, corresponding to food-to-microorganism ( F/ M) ratios of 0.34, 0.55, 0.73, 0.84, and 1.41 gCOD/gVSS d, respectively. Membrane fouling rates increased as the F/ M was increased. Steady-state membrane fouling rates were correlated with total soluble microbial products (SMP) concentrations. The membrane fouling rates did not correlate well with soluble COD measured on a 0.45 μm membrane filtrate of mixed liquor or with soluble COD rejection (effluent COD/soluble COD).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.