Abstract
Experimental studies have been undertaken that provide the fracture energy of an epoxy-steel interface that has been exposed to various uptake levels of moisture. The test configuration used for these studies is the mixed mode flexure (MMF) test. The specimens have been exposed to the moist environment as open-faced specimens. The results provided by the test show a steady degradation in the interface fracture energy with increasing moisture content. Surface characterisation techniques such as X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM) were used to characterise the nature of the failure surfaces. Both of these analyses show a reduction of adhesive fragments and carbon overlayer thickness on the steel fracture surface with increasing moisture levels. The variation of carbon overlayer thickness with moisture exhibits a similar trend as the fracture energy, indicating that the two may be related.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.