Abstract

Background:Subdiaphragmatic activity can produce subdiaphragmatic-related artifacts, which can degrade the quality of myocardial perfusion imaging (MPI).Objectives:We examined the impact of drinking milk, water, and lemon juice on different subdiaphragmatic-related artifacts by using 99mTc-sestamibi myocardial single-photon emission computed tomography (SPECT) in order to determine a feasible method for improving the image quality.Patients and Methods:A total of 179 patients (age 58 ± 9.6 years) were enrolled in this study. The patients were randomly divided into five groups. Ten minutes after injection of 740 MBq 99mTc-sestamibi in both pharmacologic stress and rest phases, the individuals in group 1 were given water and milk (125 mL of each); those in group 2 were given lemon juice (250 mL); group 3 was given milk (250 mL); and group 4 was given water (250 mL), whereas no intervention was performed in group 5. The study was double-blind for both subjects and data collectors. MPI was performed for all patients and image quality was controlled by 2 experienced nuclear physicians. Interfering activity was determined visually on reconstructed images and categorized as extracardiac normalization artifact, overlapping of activity, scattering of activity, and ramp filter artifact.Results:There were significant differences in terms of interfering activity among the five groups; group 3 (milk) had significantly lower interfering activity than other groups had, as defined by overlapping of activity (on both stress and rest images), ramp filter artifact (stress images), and scatter artifact (rest images) (P < 0.05). Furthermore, there was a significant difference in the incidence of good-quality images, with no interfering activity in group 3 in the resting state compared with the other groups in the study (P < 0.05).Conclusions:Drinking 250 mL of milk in either the stress phase or the rest phase of imaging diminishes interfering subdiaphragmatic-related artifacts, particularly overlapping of activity in MPI SPECT, resulting in better-quality images.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.