Abstract

Background In advanced clinical decision support systems, patient characteristics and laboratory values are included in the algorithms that generate alerts. These alerts have a higher specificity than basic medication surveillance alerts. The alerts of advanced clinical decision support systems can be shown directly to the prescriber during order entry, without the risk of generating an overload of irrelevant alerts. We implemented five advanced algorithms that are shown directly to the prescriber. These algorithms are for gastrointestinal prophylaxis, folic or folinic acid prescribed with orally or subcutaneously administered methotrexate, vitamin D prescribed with bisphosphonates, hyponatremia and measuring plasma levels for vancomycin and gentamicin. Objective We evaluated the effect of the implementation of the algorithms. Setting We performed prospective intervention studies with a historical group for comparison in both inpatients and outpatients at a teaching hospital in the Netherlands. Methods We compared the time period after implementation of the algorithm with the time period before implementation, using data from the hospital information system Epic. Difference in guideline adherence were analyzed using Chi square tests. Main outcome measure The outcome measures were the number of alerts, the acceptance rate of the advice in the alert, and for the algorithm measuring plasma levels for vancomycin and gentamicin the time to the correct dose. Results For all algorithms, the implementation resulted in a significant increase in guideline adherence, varying from 11 to 36%. The acceptance rate varied from 14% for hyponatremia to 90% for methotrexate. For gastrointestinal prophylaxis the acceptance rate was 4.4% for basic drug-drug interaction alerts when no gastrointestinal prophylaxis was prescribed and increased to 44.7% after implementation of the advanced algorithm. This algorithm substantially decreased the number of alerts from 812 before implementation to 217 after implementation. After implementation of the algorithm for measuring plasma levels for vancomycin and gentamicin, the proportion of patients receiving the correct dose after 48h increased from 73 to 84% (p = 0.03). Conclusion Implementation of advanced algorithms that take patient characteristics into account and are shown directly to the physician during order entry, result in an increased guideline adherence.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.