Abstract

Abstract Waste heat is an environmental issue in the world. There are some technologies that can be used to recovery the waste heat, one of which is thermoacoustic cooler technology. Thermoacoustic technology can be divided into two parts: one is thermoacoustic engine and cooler. To design the cooler system having high efficiency and lower onset heating temperature, the effect of mean pressure is investigated. By increasing mean pressure from 0.5 to 3 MPa, the heating temperature generating acoustic power can be decreased from 831 to 580 K. Moreover, 15% of Thermodynamic upper limit value of the whole cooler system is achieved.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.