Abstract

To assess the relationship of global longitudinal strain during left atrial (LA) and left ventricular (LV) filling and emptying. Using magnetic resonance imaging in 47 hypertensive patients, biplane global LV longitudinal strain was evaluated and related to LA and LV filling and emptying (by volumetric analysis), and to pulmonary vein and trans-mitral flow (by phase-contrast imaging). The results were compared to normal subjects. In hypertensive patients, reduced global longitudinal LV strain was associated with reduced LA reservoir (47±10 versus 53±9%, p<0.05), reduced LA conduit function (21±9 versus 32±11%, p<0.004), reduced LA early peak emptying rate (150±77 versus 230±88 ml/s, p=0.007), and slower early LV filling (373±141 versus 478±141 ml/s, p=0.03). LA peak filling rate showed a positive correlation to LV peak emptying rate (R=0.331, p=0.02). In hypertensive heart disease, impaired LV longitudinal systolic function causes reduced LA filling and emptying, and this leads directly to impaired LV filling and diastolic dysfunction.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.