Abstract
Tests on initially saturated and dried concrete containing a hydrophobic admixture showed that initial moisture content had a significant effect on measured water transport properties. Concrete specimens containing the hydrophobic additive significantly reduced water penetration when the concrete had been initially dried, and had limited or no positive effect on water penetration into initially saturated specimens. The reduction in water transport compared with the control was generally more pronounced in hydrophobic concrete of higher w/c ratio, as well as under conditions of limited curing and greater drying. The hydrophobic admixture had no significant effect on water vapour diffusivity. These results suggest that the ingredients in the admixture only become effective where a clear wet–dry interface is present and tend to influence water transport through larger pores.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.