Abstract
The effect of temperature and humidity on the current-voltage relationship and uniformity of positive and negative air coronas has been studied. Variations in temperature and absolute humidity seem to have a comparatively small effect on the behavior of coronas. By contrast, variations in the relative humidity have readily noticeable effects on the current-voltage relationship. At high voltages (positive or negative) the corona current decreases as the relative humidity increases due to ion and electron hydration effects. By contrast, both positive and negative coronas are initiated at lower voltages at high relative humidities, presumably due to the formation of miniscule water droplets with low ionization potential. The relative humidity also affects the uniformity of negative corona but not positive corona. Presumably the electron emitting properties of a negative wire are altered by moisture adsorbed on the wire surface at high relative humidities. By contrast, positive corona is not grossly affected because it is primarily a gas phase phenomena while negative corona is also sensitive to the electron emitting properties of the wire.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.