Abstract

AbstractThe current research is unclear regarding the sensitivity of the output of a magnetic flowmeter analysis to the fidelity of the simulated flow field. This study evaluates the effects of higher fidelity models on magnetic flowmeter analysis. An eddy viscosity model, second‐moment closure model, and a Large‐Eddy simulation were compared to laboratory velocity profile data 0.67D downstream of a 1.58D elbow at a Reynolds number of 34,000. The Large‐Eddy simulation results matched the laboratory velocity profile data best. The authors conclude that the fidelity of the flow field model does cause differences in the analysis of the flowmeter voltage output.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.