Abstract
ABSTRACTThe present work conducts an experimental investigation into the influence of flow, thermodynamic and geometrical characteristics of the wavy strip on exergy loss and dimensionless exergy loss in a tube in tube heat exchanger. The working fluid is water with hot water passing the inner tube and cold water passing annulus. Wavy strips with four different angles and three widths were investigated experimentally. The result of exergy loss and dimensionless exergy loss for various conditions is presented and on the basis of curve fitting, three empirical correlations are suggested to predict dimensionless exergy loss in a double tube heat exchanger.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.