Abstract
Intraoperative fluid management is one of the most important factors affecting optimal perfusion in the microcirculatory area in patients that undergo flap surgery. While insufficient fluid administration in the intraoperative period leads to flap complications and organ dysfunction, volume load can cause complications such as edema in the denervated flap tissue, the opening of the sutures, or fat necrosis. The Infrared Fluorescent Angiography Perfusion Evaluation Device (SPY) is one of the many noninvasive techniques that evaluate the well-being of microcirculation at the tissue level. This device monitors and scores the perfusion distribution in the flap area. This retrospective study aimed to investigate the effect of fluid resuscitation in head and neck free flap transfer surgery on flap quality and patient outcomes according to the change in SPY scores. This study included 39 ASA I-II patients who were aged 18-60 years and underwent simultaneous free flap reconstruction of the head and neck between 2015 and 2021. Patients' blood pressure, body temperature, hemoglobin, pH, and lactate values were recorded at both baseline and end of the operation. Also, the SPY "Infrared Fluorescent Angiography Perfusion Evaluation Device" scores, the amount of intraoperative fluid and transfusion, bleeding and urine output, and the duration of mechanical ventilation, anesthesia and surgery, and the duration and amount of drainage, the length of stay in hospital and intensive care unit, and the presence of flap infection, detachment, necrosis and loss, and re-exploration rate were recorded for the patients. The difference between the first and last measured SPY values was observed to be positively correlated with the length of stay in the hospital and intensive care unit and the duration of drainage. There was a positive correlation between the length of stay in the hospital and intensive care unit and the duration of drainage, the amount of drainage, as well as the duration of anesthesia and the duration of surgery (p < 0.001). A positive correlation was found between the amount of drainage and the amount of crystalloid solution administered (r = 0.36, p < 0.05). In patients with flap infection, the difference between SPYfirst and SPYlast, the duration of anesthesia, and the duration of surgery were significantly higher. The amount of crystalloid solution given and bleeding and the duration of anesthesia and surgery were found to be significantly higher in mechanically ventilated patients (p < 0.05). It has been concluded that SPY-guided fluid management can be beneficial in preventing morbidities, such as extended hospital and intensive care stay, by reducing flap infection, mechanical ventilation duration, and drainage, with early diagnosis of insufficient perfusion.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.