Abstract
The main objective of this investigation was to study the influence of an Engineered Cementitious Composite (ECC) on the seismic performances of beam–column–slab subassemblies. Tests and simulations were conducted on several models. The bearing capacity of the ECC model was 15% higher than that of the RC member, the deformability increased by 19%, and the energy dissipation capability increased by 34%. The use of an ECC in the slab could reduce the contribution of the reinforced bars in the slab to the flexural strength of the beam. At a drift of 2%, the range of the yielding bars in the slab of the RC models was 5h to 6h. However, the yield range of reinforcement in the slab of the ECC models was nearly 3h. As a result, the ECC subassemblies were prone to reach a “strong column and weak beam” yield mechanism.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.