Abstract

This paper presents the results of an experimental study conducted on a multi-tank thermal storage. The purpose of the study was to investigate the thermal behaviour of the stratified tank system when subjected to standard draw profiles. The experimental set up consisted of a charge loop to simulate a solar collector input, three commercially available 270 L domestic hot water tanks and three side-arm, natural convection heat exchangers. The system was charged using two 3kW electric heaters which produced a variable input power to simulate the variation in output of a typical fixed orientation solar collector. Realistic hot water draws were conducted according to the specifications of the Canadian Standard Association, CSA-F379.1, for Solar Domestic Hot Water Systems. Tests were performed over 2 days for three different plumbing configurations, and compared with simulated results produced in the TRNSYS simulation environment. Comparisons between system configurations were based on stratification levels and hot water delivery temperatures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.