Abstract

PurposeTo measure the effect of different tooth preparation finishing procedures (super-coarse grit, fine grit, and air-particle abrasion) and immediate dentin sealing (IDS) on the scanning accuracy of 4 intraoral scanners (IOSs). Material and methodsA tooth preparation for a full-coverage restoration was performed on an extracted mandibular molar using super-coarse diamond burs. Four groups were created depending on the tooth preparation finishing procedure: super-coarse grit (bur with a grit size of 150 µm) (SCG group), fine grit (bur with a grit size of 30 µm) (FG), air-particle abrasion with 27-µm aluminum oxide particles (APA group), and IDS (IDS group). Each group was divided into 5 subgroups according to the scanning system used to digitize the tooth preparation: laboratory scanner (control subgroup) (T710; Medit), Trios 4 (Trios subgroup), CS 3800 (CS subgroup), i700 wireless (i700 subgroup), and iTero Element 5D Plus (iTero subgroup) (n=20). For each subgroup, the control file was aligned with each experimental scan using the best-fit algorithm and an engineering program (Geomagic Control X). The discrepancy between the control and experimental files of each subgroup was computed by measuring the root mean square (RMS) error. Two-way ANOVA and Tukey tests were used to analyze the data (α=.05). ResultsTooth preparation finishing procedures (P<.001) and the IOS assessed (P<.001) were significant predictors of the trueness and precision values obtained. The highest trueness and precision values were measured in the APA group, while the IDS group had the lowest trueness and precision. Additionally, the i700 subgroup obtained the highest trueness and precision values, while the CS and Trios subgroups had the lowest trueness and precision values. ConclusionsThe different tooth preparations finishing procedures tested influenced on the scanning accuracy of the 4 IOSs considered. The air-particle abrasion procedure obtained the best accuracy values. The trueness discrepancies measured among all the subgroups was 19µm and the precision discrepancies measured among all the subgroups was 4.69 µm. Clinical SignificanceThe tooth preparation finishing procedure used can reduce the intraoral scanning accuracy of any of the intraoral scanners tested. The air-particle abrasion finishing procedure might be recommended for maximizing the scanning accuracy of the IOSs tested.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call