Abstract

Abstract The difficulties of using an aluminium/Polythene penetrameter for accurate and reliable measurement of the kilovoltage of an X-ray machine are discussed. Its behaviour in the region 25–45 kVp has been investigated by a computer simulation technique. Starting with Kramers' Theory of spectral distribution, the intensity of radiation emerging from the penetrameter was calculated. The optical density on non-screen film was then derived using the known properties of the emulsion. It is shown that, within wide limits, neither the voltage and current wave forms nor the values of the tube nitration significantly affect the calibration of the penetrameter. This conclusion is shown to be in agreement with experimental measurements.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.