Abstract

The effect of co-occurring inorganic solutes existence in feed water on the removal of arsenic (V) and permeate flux was investigated for the treatment process using a cationic surfactant cetylpyridinium chloride (CPC) and a 5 kilo-Dalton (kDa) polyethersulfone (PES) membrane. Simulated water and well water (Washoe County STMGID #9 operational well, Nevada) were used for this study. The concentrations of arsenic ([As] F = 0−105 μg/L) and inorganic solutes ([HCO − 3] = 0−4.1 mg/L, [HPO 2− 4] = 0−0.3 mg/L, [H 4SiO 4] = 0−90 mg/L, and [SO 2− 4] = 0−400 mg/L) in simulated feed water were varied. The pH level of simulated feed water was adjusted to 8 since the well water pH was around 8. The arsenic concentration in the well water was 73 μg/L. The concentrations of carbonate, phosphate, silicate, and sulfate in the well water were 1 mg/L, 0.17 mg/L, 69 mg/L, and 8.2 mg/L, respectively. PES membrane without surfactant micelles was found to be ineffective for arsenic removal. The highest arsenic removal in the presence of inorganic solutes is 25%, corresponding to a permeate water arsenic concentration of 30 μg/L which is well above the new maximum contaminant level (MCL) of 10 μg/L. With the addition of 10 mM CPC to the feed water, the arsenic removal efficiency is significantly increased ranging between 78.1% and 100%. The arsenic removal efficiency was found to be dependent on the feed water arsenic and co-occurring inorganic solute concentrations. Except for one UF experiment performed with the simulated feed water containing 105 μg/L arsenic and 400 mg/L SO 2− 4 (23 μg/L arsenic in permeate water), all the other UF experiments produced permeate water with arsenic below the new MCL. The presence of HCO − 3, HPO 2− 4, and H 4SiO 4 species in feed water does not affect the arsenic removal efficiency (100%) except in one case (99% removal efficiency for the feed water containing 105 μg/L arsenic and 90 mg/L H 4SiO 4). The experiments performed with well water result in almost 100% arsenic removal (arsenic level in permeate water is below the detection limit of ICP-MS, 1 μg/L). Furthermore, absolute permeate flux was also found to be dependent on the feed water arsenic and co-occuring inorganic solute concentrations. An increase in feed water arsenic concentration results in a decrease in the permeate flux. For the experiments performed with simulated water containing CPC and arsenic, the permeate water flux is 56.5 ± 2.5% of ultra clean water flux. The permeate flux reduces further as the co-occuring inorganic solute concentration or the total dissolved solid in feed water increases. It is 43.5 ± 3.5%, 45.5 ± 7.5%, 43.5 ± 6.5%, and 37.5 ± 5.5% of the ultra clean water flux for the simulated water containing HCO − 3, HPO 2− 4, H 4SiO 4 and SO 2− 4 species, respectively. With the well water, permeate flux was found to be 33% of the ultra clean water flux. Only 1.52 ± 0.33% of the surfactant molecules used were detected in permeate water. Surfactants in permeate water can be further separated and reused in the feed stream.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call