Abstract

Aortic dissection (AD) is one of the fatal and complex conditions. Since there is a lack of a specific treatment guideline for type-B AD, a better understanding of patient-specific hemodynamics and therapy outcomes can potentially control the progression of the disease and aid in the clinical decision-making process. In this work, a patient-specific geometry of type-B AD is reconstructed from computed tomography images, and a numerical simulation using personalised computational fluid dynamics (CFD) with three-element Windkessel model boundary condition at each outlet is implemented. According to the physiological response of beta-blockers to the reduction of left ventricular contractions, three case studies with different heart rates are created. Several hemodynamic features, including time-averaged wall shear stress (TAWSS), highly oscillatory, low magnitude shear (HOLMES), and flow pattern are investigated and compared between each case. Results show that decreasing TAWSS, which is caused by the reduction of the velocity gradient, prevents vessel wall at entry tear from rupture. Additionally, with the increase in HOLMES value at distal false lumen, calcification and plaque formation in the moderate and regular-heart rate cases are successfully controlled. This work demonstrates how CFD methods with non-invasive hemodynamic metrics can be developed to predict the hemodynamic changes before medication or other invasive operations. These consequences can be a powerful framework for clinicians and surgical communities to improve their diagnostic and pre-procedural planning.

Highlights

  • Aortic dissection (AD) is one of the fatal and complex conditions

  • It leads to create a channel by communicating the main bloodstream or true lumen (TL) of the aorta into a false lumen (FL), which is separated by an intimal flap (IF)

  • The velocity decreases with the heart rate reduction at all cardiac points except pick systole, where no significant changes can be seen

Read more

Summary

Introduction

Since there is a lack of a specific treatment guideline for type-B AD, a better understanding of patient-specific hemodynamics and therapy outcomes can potentially control the progression of the disease and aid in the clinical decision-making process. Aortic dissection (AD) is a subset of cardiovascular disease, which occurs when an injury to the intima layer enables blood to enter the middle layer of the aortic wall It leads to create a channel by communicating the main bloodstream or true lumen (TL) of the aorta into a false lumen (FL), which is separated by an intimal flap (IF). Several studies have reported the importance of personalised computational fluid dynamics (CFD) methods along with imaging techniques to develop diagnosis and controlling approaches of aortic disease, in order to customize patient-specific treatment o­ utcomes[23,24,25,26,27,28,29]. The present study aims to highlight the effectiveness of using the pharmaceutical treatment on type-B AD in terms of progression, planning, and management

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call