Abstract

To examine the effect of auto-positive end-expiratory pressure (autoPEEP) on the estimation of arterial carbon dioxide pressure (PaCO 2) from end-tidal carbon dioxide pressure (PetCO 2) during changes in minute ventilation (MV), we studied 24 consecutive sedated and paralyzed patients under controlled mechanical ventilation for acute respiratory failure. The patients were grouped according to whether they had autoPEEP: group I (n = 11) comprised non-autoPEEP patients and group II (n = 13) comprised autoPEEP patients. Patients were randomly ventilated at three different levels of MV: normal MV (basal tidal volume), high MV (tidal volume 2.5 mL/kg above basal), and low MV (tidal volume 2.5 mL/ kg below basal). Respiratory rate and inspiration to expiration ratio were kept constant during the study. In each condition, we measured arterial blood gases, expiratory capnograms, airway pressure, and autoPEEP. We determined PaCO 2-PetCO 2 gradient, predicted PaCo 2 (Pa'CO 2) [Pa'CO 2 = PetCO 2 for each condition + (PaCO 2 PetCO 2 gradient at normal MV)], and expired CO 2 slope. The PaCO 2-PetCO 2 gradient only remained stable in group I (mean values for low, normal, and high MV were 3.3, 3.3, and 3.5 mm Hg, respectively), while group II showed a significant difference during low MV (12.2 mm Hg) when compared with normal MV (8.4 mm Hg; P < .01) and high MV (8.9 mm Hg; P < .05). PaCO 2 and PetCO 2 showed significant correlations in both groups ( r = .92 in group I and .79 in group II). However, Pa'CO 2 could only be safely estimated in patients without autoPEEP when the difference between PaCO 2 and Pa'CO 2, ranged between 1.6 and −1.9 mm Hg. Slopes of expired CO 2 greater than 3 mm Hg/s identified patients with autoPEEP of 89% sensitivity, 93% specificity, 94% positive predictive power, and 95% accuracy. A significant correlation was found between autoPEEP and expired CO 2 slope ( r = .70; P < .001), between autoPEEP and PaCO 2-PetCO 2 gradient ( r = .46; P < .001), and between CO 2 expired slope and PaCO 2 PetCO 2 gradient ( r = .74; P < .001). These results indicate that in patients with acute respiratory failure under controlled mechanical ventilation, the presence of autoPEEP is associated with inaccuracy in the calculation of predicted PacoZ from PetcoZ after changes in MV at fixed respiratory rates.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.