Abstract

To examine the effect of adding artificial tears for one minute to normal eyes and eyes that have undergone keratoplasty by using computer-assisted videokeratography. We prospectively analyzed 24 normal corneas (24 patients) chosen by random number table (reproducibility section [10 eyes], tear section [14 eyes]) as well as 14 postkeratoplasty corneas. The parametric descriptors analyzed statistically included the simulated keratometry value, surface asymmetry index, surface regularity index, power at the vertex normal, and the pupil offsets from the visual axis. Vectoral analysis was used to calculate the difference in power and axis between the simulated keratometry values before and after tear instillation. In normal eyes, tear instillation increased the surface asymmetry index (0.28 +/- 0.34, P = .01), changed the simulated keratometry value (0.23 diopter by 27.8 degrees), and power (0.79 +/- 0.82 diopters, P = .004) and location (0.91 +/- 0.76 mm) of the steepest point of the cornea changed. In postkeratoplasty eyes, the surface regularity index decreased (0.49 +/- 0.80, P = .04), surface asymmetry index decreased (0.37 +/- 1.03, P = .21), mean simulated keratometry value changed (1.04 diopters by 1.01 degrees), and power (0.70 +/- 2.34 diopters, P = .28) and location (1.04 +/- 1.17 mm) of the steepest point of the cornea changed. Changes were greater than the variability of the surface regularity index (0.07 +/- 0.05), surface asymmetry index (0.04 +/- 0.03), simulated keratometry value power (0.08 +/- 0.06 diopter), and axis (4.6 +/- 5 degrees). The addition of artificial tears to normal or regular and symmetric eyes that have undergone keratoplasty worsened symmetry and changed the power and location of the steepest point. However, the addition of artificial tears to irregular eyes that have undergone penetrating keratoplasty created a more regular and symmetric surface and significantly altered the simulated keratometry values. We recommend that corneal topography be performed before the application of artificial tears.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.