Abstract

The causes of anomalous behavior of the Hall mobility of charge carriers as a result of a decrease in the measurement temperature from 300 K in indium-antimonide films obtained by the method of three temperatures are studied. It is shown experimentally that there exist drops in the “admissible” temperatures of evaporators of components and the substrate within which continuous conducting films are obtained. The optimal conditions for sample preparation for which the values of the mobility remain practically constant in the temperature range of 150–350 K are determined. On the basis of the comparison with optical-transmission spectra, it is concluded that there is a high concentration of defects in the films; these defects are related to deviation of the composition from stoichiometry and act as donor and acceptor centers. The presence of such defects makes it possible to explain the decrease in mobility in the films as the temperature is lowered.