Abstract

This study examined the effect of an on-frequency precursor on growth-of-masking (GOM) functions measured using an off-frequency masker. The signal was a 6-ms, 4-kHz tone. A GOM function was measured using a 40-ms, 2.8-kHz tone (the off-frequency masker). GOM functions were then measured with an on-frequency, fixed level precursor presented before the off-frequency masker. The precursor was 50 or 60 dB SPL, and 160 ms in duration. For the 60-dB SPL precursor, a 40-ms duration was also used. Two-line functions were fit to the GOM data to estimate the basilar membrane input-output function. The precursors reduced the gain of the input-output function, and this decrease was graded with precursor level. Both precursor durations had the same effect on gain. Changes in masking following a precursor were larger than would be predicted by additivity of masking. The observed decrease in gain may be consistent with activation of the medial olivocochlear reflex by the precursor.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.