Abstract

Objective: In order to provide a theoretical basis for the revision of the current diagnostic criteria for occupational noise-induced deafness (ONID), we evaluated the degree of ONID by analyzing different high-frequency-hearing- threshold-weighted values (HFTWVs). Methods: A retrospective study was conducted to evaluate the diagnosis of patients with ONID from January 2016 to January 2017 in Guangdong province, China. Based on 3 hearing tests (each interval between the tests was greater than 3 days), the minimum threshold value of each frequency was obtained using the 2007 edition’s diagnostic criteria for ONID. The speech frequency and the HFTWVs were analyzed based on age, noise exposure, and diagnostic classi-fication using SPSS21.0. Results: 168 patients in total were involved in this study, 154 males and 14 females, and the average age was 41.18 ± 6.07. The diagnosis rate was increased by the weighted value of the high frequencies and was more than the mean value of the pure speech frequency (MVPSF). The diagnosis rate for the weighted 4 kHz frequency level increased by 13.69% (χ2 = 9.880, P = 0.002), the weighted 6 kHz level increased by 15.47% (χ2 = 9.985, P = 0.002), and the weighted 4 kHz + 6 kHz level increased by 15.47% (χ2 = 9.985, P = 0.002). The differences were all statistically significant. The diagnostic rate of the different thresholds showed no obvious difference between the genders. The age groups were divided into less than or equal to 40 years old (group A) and 40 - 50 years old (group B). There were several groups with a high frequency: high frequency weighted 4 kHz ( group A χ2 = 3.380, P = 0.050; group B χ2 = 4.054, P = 0.032), high frequency weighted 6 kHz (group A χ2 = 6.362, P = 0.012; group B χ2 = 4.054, P = 0.032), weighted 4 kHz + 6 kHz (group A χ2 = 6.362 P = 0.012; B χ2 = 4.054, P = 0.032) than those of MVPSF in the same group on ONID diagnosis rate. The differences between the groups were statistically significant. There was no significant difference between the age groups (χ2 = 2.265, P = 0.944). The better ear’s (the smaller hearing threshold weighted value) MVPSF and the weighted values for the different high frequencies were examined in light of the number of working years; the group that was exposed to noise for more than 10 years had significantly higher values than those of the average thresholds of each frequency band in the groups with 3 - 5 years of exposure (F = 2.271, P = 0.001) and 6 - 10 years of exposure (F = 1.563, P = 0.046). The differences were statistically significant. The different HFTWVs were higher than those of the MVPSF values, and the high frequency weighted 4 kHz + 6 kHz level showed the greatest difference, with an average increase of 2.83 dB. The diagnostic rate that included the weighted high frequency values was higher for the mild, moderate, and severe cases than those patients who were only screened with the pure frequency tests. The results of the comparisons of the diagnosis rates for mild ONID were as follows: the weighted 3 kHz high frequency level (χ2 = 3.117, P = 0.077) had no significant difference, but the weighted 4 kHz level (χ2 = 10.835, P = 0.001), 6 kHz level (χ2 = 9.985, P = 0.002), 3 kHz + 4 kHz level (χ2 = 6.315, P = 0.012), 3 kHz + 6 kHz level (χ2 = 6.315, P = 0.012), 4 kHz + 6 kHz level (χ2 = 9.985, P = 0.002), and 3 kHz + 4 kHz + 6 kHz level (χ2 = 7.667, P = 0.002) were significantly higher than the diagnosis rate of the mean value of the PSF. There was no significant difference between the 2 groups for the moderate and severe grades (P > 0.05). Conclusion: Different HFTWVs increase the diagnostic rate of ONID. The weighted 4 kHz, 6 kHz, and 4 kHz + 6 kHz high frequency values greatly affected the diagnostic results, and the weighted 4 kHz + 6 kHz high frequency hearing threshold value has the maximum the effect on the ONID diagnosis results.

Highlights

  • Noise is an important problem in many societies, either in the workplace or outside of it [1]

  • In order to provide a theoretical basis for the revision of the current diagnostic criteria for occupational noise-induced deafness (ONID), we evaluated the degree of ONID by analyzing different high-frequency-hearingthreshold-weighted values (HFTWVs)

  • The purpose of this study was to elucidate whether the inclusion of different frequency thresholds had an effect on the ONID diagnosis; there was an attempt to illuminate the extent and magnitude of the impact, eventually providing a theoretical basis for the revision of the diagnostic criteria for ONID

Read more

Summary

Introduction

Noise is an important problem in many societies, either in the workplace or outside of it [1]. Approximately 5% of the world’s population suffers from noise-induced hearing loss (NIHL) acquired from industrial occupations, military duty and combat, and recreation and leisure activities. The diagnostic criteria for ONID in China were revised 4 times from 1996 (GB16152-1996 Diagnostic Criteria and Management of Occupational Noise-induced Deafness) [6] to 2014 (GB49-2014 Diagnosis of Occupational Noise-induced Deafness) [7], and the largest difference was included in the 10% 4 kHz HFTWV on the basis of the 90% MVPSF. The purpose of this study was to compare the results and degrees of ONID in light of the different HFTWVs and provide a theoretical basis for the revision of ONID diagnosis standards

Research Subjects
Inclusion Criteria
Exclusion Criteria
Research Group
Pure Tone Audiometry
Auditory Threshold Calculation Method
Statistical Treatment
Basic Characteristics of All Subjects
Discussion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call