Abstract
Protective gear is mandatory for medical personnel treating casualties in a contaminated environment. In the present study, we assessed the ability of emergency medical technicians to insert an intravenous line in this situation. Sixty emergency medical technicians were randomized to a control group, wearing fatigues, and a study group, wearing full protective gear. The ability to insert an intravenous line in healthy volunteers was assessed 1, 2, 4, and 8 hours after randomization. We found no effect of protective gear (p = 0.543) or time in protective gear (p = 0.8869) on success rate or on time needed for successful task completion (p = 0.4005 and p = 0.9021, respectively). The overall success rate was 58.6%, 65% in the unprotected state and 56% in the protected state, and the time was 303 +/- 115 and 351 +/- 113 seconds, respectively. These findings suggest that introduction of an intravenous line is possible but time consuming even after a prolonged stay in full protective gear. Alternative methods for antidotal treatment, such as the use of automatic autoinjectors for intramuscular administration, might be suggested.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.