Abstract

The objectives of this study were to assess the effect of 2 different premilking stimulation regimens, with and without a latency period between tactile stimulation and the attachment of the milking unit, on the teat tissue condition and milking performance of dairy cows. In a randomized controlled crossover study, 145 Holstein cows milked 3 times daily were assigned to treatment (TRT) or control (CON) groups. Premilking udder preparation for the TRT group consisted of the application of a latency period resulting in a preparation lag time of 90 s. The only difference in the premilking udder preparation of the CON group was the absence of latency period; the milking unit was attached immediately after completion of the tactile stimulation. The average duration of total tactile stimulation in TRT and CON group was 8 ± 2 and 9 ± 2 s, respectively. The study lasted for 14 d and was split into 2 periods, each consisting of a 2-d adjustment period followed by 5 d of data collection. We assessed machine milking-induced short-term changes to the teat tissue by palpation and visual inspection postmilking. Electronic on-farm milk meters were used to assess milking characteristics (milk yield [kg/milking session], machine-on time [s], 2-min milk yield [kg], and duration of low milk flow rate [s]). Generalized linear mixed models were used to analyze the effect of treatment on the outcome variables. The odds of machine milking-induced short-term changes to the teat tissue were lower for cows that received a 90-s preparation lag time (TRT cows) compared with cows in the CON group (odds ratio [95% confidence interval; 95% CI] = 0.13 [0.08-0.20]). The least squares means (95% CI) values of cows in the TRT and CON groups were 15.4 (14.9-15.9) and 15.3 (14.8-15.8) kg, respectively, for milk yield, and 246 (239-253) and 253 (247-260) s for machine-on time. The 2-min milk yield was higher for the TRT compared with CON group cows at all the parity levels. The 2-min milk yields of animals in lactation 1, 2, and ≥3 were 5.7, 5.7, and 6.5 kg, respectively, in the TRT group and 4.6, 5.0, and 5.9 kg in the CON group. The TRT cows spent less time in low milk flow rate compared with CON cows at all parity levels. The durations of low milk flow rate of cows in lactation 1, 2, and ≥3 in the TRT group were 19, 17 and 13 s, respectively, and those in the CON group were 31, 22, and 15 s. In this study, cows that received a latency period, and thus were subjected to a 90-s preparation lag time had lower odds of exhibiting short-term changes to the teat tissue after machine milking, shorter machine-on time, higher 2-min milk yields, and lower durations of low milk flow rates. We conclude that consideration of latency period leading to a 90-s preparation lag time in the premilking stimulation regimen facilitated cows' milk-ejection reflex. This latency period can alleviate the adverse effects of vacuum-induced forces on teat tissue during machine milking, improve udder health, and promote animal well-being.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.