Abstract

When the ground would be excavated and retained adjacent to the existing structure, earth pressure acting on the rigid wall of the existing structure could be changed depending on its separation distance from the retaining wall, its wall friction, and the deformation of retaining wall. Model tests were conducted in the uniform sandy ground for various separation distances and wall frictions. Test equipment consisted of the model test box, the rigid wall and the earth retaining wall. Location of the retained earth wall was varied. They were 0.4H, 0.8H and 1.2 H (H is the height of rigid wall). Friction angle of the rigid wall was varied. They were 0, ϕ/3, 2ϕ/3. The earth pressure on the rigid wall was changed under the influence of the deformation of retaining wall, the separation distance of the retaining wall, and the friction of rigid wall. It was found out that the separation distance has more effects on the earth pressure reduction than that of the wall friction. Change of earth pressure on the rigid wall induced by the ground excavation adjacent to it was affected by the friction of rigid wall, the separation distance, and the displacement of earth retaining walls. Earth pressure on a rigid wall was reduced in a larger amount when the wall friction of rigid wall increased.

Highlights

  • When a ground is excavated and retained adjacent to the rigid wall of the existing substructure, the earth pressure acting on it could be changed.Earth pressure on the rigid wall could be changed depending on the separation distance between retaining wall and rigid wall, the deformation of retaining wall and the wall friction of rigid wall (Lee 2014)

  • The model tests were performed in a sandy ground in order to find out the variation of earth pressure acting on the rigid wall of the existing substructure when the retained earth wall deformed adjacent to the rigid wall

  • Earth pressure acting on the rigid wall depended on the separation distance, the wall friction angle, and the horizontal displacement of earth retaining wall

Read more

Summary

Methods

Model tests were conducted in the uniform sandy ground for various separation distances and wall frictions. Test equipment consisted of the model test box, the rigid wall and the earth retaining wall. Location of the retained earth wall was varied. They were 0.4H, 0.8H and 1.2 H (H is the height of rigid wall). Friction angle of the rigid wall was varied

Results
Conclusions
Introduction
Conclusion
Results are as follows:
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call