Abstract

IntroductionNuclear medicine parathyroid imaging is important in the identification of hyperfunctioning parathyroid glands in primary hyperparathyroidism (pHPT), but it may be also valuable before surgical treatment in secondary hyperparathyroidism (sHPT). Parathyroid radionuclide imaging with scintigraphy or positron emission tomography (PET) is a highly sensitive procedure for the assessment of the presence and number of hyperfunctioning parathyroid glands, located either at typical sites or ectopically. The treatment of pHPT is mostly directed toward minimally invasive parathyroidectomy, especially in cases with a single adenoma. In experienced hands, successful surgery depends mainly on the exact preoperative localization of one or more hyperfunctioning parathyroid adenomas. Failure to preoperatively identify the hyperfunctioning parathyroid gland challenges minimally invasive parathyroidectomy and might require bilateral open neck exploration.MethodsOver a decade has now passed since the European Association of Nuclear Medicine (EANM) issued the first edition of the guideline on parathyroid imaging, and a number of new insights and techniques have been developed since. The aim of the present document is to provide state-of-the-art guidelines for nuclear medicine physicians performing parathyroid scintigraphy, single-photon emission computed tomography/computed tomography (SPECT/CT), positron emission tomography/computed tomography (PET/CT), and positron emission tomography/magnetic resonance imaging (PET/MRI) in patients with pHPT, as well as in those with sHPT.ConclusionThese guidelines are written and authorized by the EANM to promote optimal parathyroid imaging. They will assist nuclear medicine physicians in the detection and correct localization of hyperfunctioning parathyroid lesions.

Highlights

  • Nuclear medicine parathyroid imaging is important in the identification of hyperfunctioning parathyroid glands in primary hyperparathyroidism, but it may be valuable before surgical treatment in secondary hyperparathyroidism

  • Fine-needle aspiration cytology is recommended in highly selected cases, e.g., atypical cervical ultrasonography (cUS) presentation and uninformative [99mTc]Tc-MIBI

  • A 10% energy window centered on the 159 keV is recommended for Na[123I]I and a 15–20% window centered around 140 keV for [99mTc]Tc-MIBI

Read more

Summary

Methods

Over a decade has passed since the European Association of Nuclear Medicine (EANM) issued the first edition of the guideline on parathyroid imaging, and a number of new insights and techniques have been developed since. The aim of the present document is to provide state-of-the-art guidelines for nuclear medicine physicians performing parathyroid scintigraphy, single-photon emission computed tomography/computed tomography (SPECT/CT), positron emission tomography/computed tomography (PET/CT), and positron emission tomography/magnetic resonance imaging (PET/MRI) in patients with pHPT, as well as in those with sHPT

Conclusion
Introduction
Background
Conclusions
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call