Abstract

A procedure for calculating the response of an array to a harmonic excitation applied at the upstream end is presented. The fluid forces on the array are modeled following the slender-body approximation and the cross-flow principle. An equivalent linear damping is used to replace the quadratic drag due to cross-flow separation. The equivalent linear damping is determined using an iterative procedure. Numerical and asymptotic solutions are derived, and the response of a typical long array is calculated. It is found that, when the separation drag is included, the array exhibits the behavior of an over-damped system, responding only to low-frequency excitations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.