Abstract

Traditionally, arthrocentesis involves insertion of 2 needles into the joint space of which one acts as an inflow port and the other as the outflow port. These 2 needles must triangulate and be exactly placed in the upper joint space for the procedure to be effective. Due to the difficulty in maintaining the needle position, single-puncture arthrocentesis is gaining popularity. It is relatively easier to perform and less traumatic to the joint. The authors describe a simple technique of single-puncture arthrocentesis using parts of 2 peripheral intravenous catheters of different gauges. The outflow port is formed by the catheter tube of 1 cannula while the inflow port is formed by the needle of the second cannula. Besides beings easy to perform and cost-effective, our technique provides predictable joint lavage of the joint with minimal trauma to the tissues.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.