Abstract
To determine the daily and cumulative dosimetric effects of intrafraction prostate motion on step-and-shoot (SNS) intensity-modulated radiation therapy (IMRT) plans, to evaluate the correlation of dosimetric effect with motion-based metrics, and to compare on a fraction-by-fraction basis the dosimetric effect induced in SNS and helical tomotherapy plans. Intrafraction prostate motion data from 486 fractions and 15 patients were available. A motion-encoded dose calculation technique was used to determine the variation of the clinical target volume (CTV) D(95%) values with respect to the static plan for SNS plans. The motion data were analyzed separately, and the correlation coefficients between various motion-based metrics and the dosimetric effect were determined. The dosimetric impact was compared with that incurred during another IMRT technique to assess correlation across different delivery techniques. The mean (±1 standard deviation [SD]) change in D(95%) in the CTV over all 486 fractions was 0.2 ± 0.5%. After the delivery of five and 12 fractions, the mean (±1 SD) changes over the 15 patients in CTV D(95%) were 0.0 ± 0.2% and 0.1 ± 0.2%, respectively. The correlation coefficients between the CTV D(95%) changes and the evaluated motion metrics were, in general, poor and ranged from r = -0.2 to r = -0.39. Dosimetric effects introduced by identical motion in SNS and helical tomotherapy IMRT techniques were poorly correlated with a correlation coefficient of r = 0.32 for the CTV. The dosimetric impact of intrafraction prostate motion on the CTV is, in general, small. In only 4% of all fractions did the dosimetric consequence exceed 1% in the CTV. As expected, the cumulative effect was further reduced with fractionation. The poor correlations between the calculated motion parameters and the subsequent dosimetric effect implies that motion-based thresholds are of limited value in predicting the dosimetric impact of intrafraction motion. The dosimetric effects between the two evaluated delivery techniques were poorly correlated.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Radiation Oncology*Biology*Physics
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.