Abstract

Dose distributions in water have been measured using LiF thermoluminescent dosimeters for 192Ir seed sources with stainless steel and with platinum encapsulation to determine the effect of differing encapsulation. The dose distribution has also been measured for a 137Cs seed source. In addition, dose distributions surrounding these sources have been calculated using the EGS4 Monte Carlo code and have been compared to the measured data. The two methods are in good agreement for all three sources. Tables are given which describe the dose distribution surrounding each source as a function of distance and angle. In addition, specific dose constants have been determined from results of Monte Carlo simulation. This work has confirmed the utility of the EGS4 Monte Carlo code in modelling 192Ir and 137Cs seed sources to obtain brachytherapy dose distributions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.