Abstract

1. Of the glucose in rat blood 79.8+/-3.3% (s.d.) was in the plasma. The variance was mostly due to differences between rats. 2. The concentration of glucose in erythrocyte water was 51+/-8% (s.d.) of that in plasma water. 3. The ratio (specific radioactivity in plasma)/(specific radioactivity in whole blood), i.e. the P/B ratio, was estimated for glucose at intervals after intravenous injection of [U-(14)C]glucose and [U-(14)C]fructose. The ratio differed from unity by more than the standard error of a single determination of the specific radioactivity of blood or plasma glucose except from 10 to 17min. after injection of [(14)C]glucose and from 22 to 30min. after injection of [(14)C]fructose. At all other times specific radioactivities in blood had to be corrected to give specific radioactivities in plasma. How to do so is described. 4. The P/B ratios were accounted for by a turnover of glucose in erythrocytes of 0.14mumole/min./ml. of erythrocytes. 5. Metabolism of glucose in rat erythrocytes is unlikely to be a major source of lactate.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.