Abstract

Flows in technical and natural circuits often involve a particulate phase. To measure the dynamics of suspended, naturally resident or artificially seeded particles in the flow, optical measuring techniques, e.g., laser Doppler anemometry (LDA) can be used advantageously. In this paper the dispersion of particles in a single-sided backward-facing step flow is investigated by LDA. The investigation is of relevance for both, two-phase flow problems in separated flows with the associated particle diameter range of 1–70 μm and the accuracy of LDA with tracer particles of different sizes. The latter is of interest for all LDA applications to measure continuous phase properties, where interest for experimental restraints require tracer diameters in the upper micrometer range, e.g., flame resistant particles for measurements inside reactors, cylinders, etc. For the experiments, a closed-loop wind tunnel with a step expansion was used. Part of this tunnel, the test section, was made of glass. The step had a height H=25 mm (channel height before the step 25 mm, after 50 mm, i.e., an expansion ratio of 2). The width of the channel was 500 mm. The length of the glass test section was chosen as 116 step heights. The wind tunnel, driven by a radial fan, allowed flow velocities up to 50 m/sec which is equivalent to ReH=105. Seeding was performed with particles of well-known size: 1, 15, 30, and 70 μm in diameter. As 1 μm tracers oil droplets were used, whereas for the upper micron range starch particles (density 1.500 kg/m3) were chosen. Starch particles have a spherical shape and are not soluble in cold water. Particle velocities were measured locally using a conventional 1-D LDA system. The measurements deliver the resultant ‘‘flow’’ field information stemming from different particle size classes. Thus, the particle behavior in the separated flow field can be resolved. The results show that with increasing particle size, the particle velocity field differs increasingly from the flow field of the continuous phase (inferred from the smallest tracers used). The velocity fluctuations successively decrease with increasing particle diameter. In separation zones, bigger particles have a lower mean velocity than smaller ones. The opposite holds for the streamwise portions of the particle velocity field, where bigger particles show a higher velocity. The measurements give detailed insight into the particle dynamics in separated flow regions. LDA-measured dividing streamlines and lines of zero velocity of different particle classes in the recirculation region have been plotted and compared. In LDA the use of tracer particles in the upper micrometer size range leads to erroneous determinations of continuous phase flow characteristics. It turned out that the dimensions of the measured recirculation zones are reduced with increasing particle diameter. The physical reasons for these findings (relaxation time of particles, Stokes numbers, etc.) are explained in detail.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call