Abstract
The build-factor is a magnitude which allows to correct the photon exponential attenuation model to obtain the real value of a certain dosimetric magnitude, like air exposure. Its main weaknesses are the dependences on the response function of such a magnitude, the geometry, and the source directionality. A formalism to deal with the first is presented in this work, which leads to the definition of the differential build-up factor. Analog Monte Carlo calculations were used to calculate this factor, as well as describing its uncertainty, in the 30 keV to 10 MeV energy range for the most typical materials up to 10 mean-free-paths. Coherent scattering and binding effects were considered in the simulations, which make the results suitable for calculations with the most complete descriptions of the attenuation coefficients. Differences due to geometry, source directionality, and detector response variability were typically found to be up to 30 % in the studied range.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.