Background/Aims: The aim of this study was to examine the impact of different catheter tip positions on the life of the catheter, dysfunction, infection, and quality of hemodialysis and possible differences between the access site laterality in jugular-tunneled hemodialysis catheters. Methods: Catheters were evaluated for the following parameters: place of insertion, time of insertion, duration of use, and reason for removal. In all patients, the catheter tip position was checked using an X-ray. Results: The mean duration of implanted catheters with the tip placed in the cavo-atrial junction and right atrium was significantly longer. There were no differences in catheter functionality at follow-up or complications based on catheter laterality for each catheter tip position. Conclusion: According to our results, the localization of the catheter tip in superior vena cava still remains the least preferable method. Our results showed that the main factor responsible for better catheter functionality was not laterality but the depth to which the catheter tip is inserted into the body.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.