BackgroundWith the diabetes mellitus (DM) prevalence increasing annually, the human grading of retinal images to evaluate DR has posed a substantial burden worldwide. SmartEye is a recently developed fundus image processing and analysis system with lesion quantification function for DR screening. It is sensitive to the lesion area and can automatically identify the lesion position and size. We reported the diabetic retinopathy (DR) grading results of SmartEye versus ophthalmologists in analyzing images captured with non-mydriatic fundus cameras in community healthcare centers, as well as DR lesion quantitative analysis results on different disease stages.MethodsThis is a cross-sectional study. All the fundus images were collected from the Shanghai Diabetic Eye Study in Diabetics (SDES) program from Apr 2016 to Aug 2017. 19,904 fundus images were acquired from 6013 diabetic patients. The grading results of ophthalmologists and SmartEye are compared. Lesion quantification of several images at different DR stages is also presented.ResultsThe sensitivity for diagnosing no DR, mild NPDR (non-proliferative diabetic retinopathy), moderate NPDR, severe NPDR, PDR (proliferative diabetic retinopathy) are 86.19, 83.18, 88.64, 89.59, and 85.02%. The specificity are 63.07, 70.96, 64.16, 70.38, and 74.79%, respectively. The AUC are PDR, 0.80 (0.79, 0.81); severe NPDR, 0.80 (0.79, 0.80); moderate NPDR, 0.77 (0.76, 0.77); and mild NPDR, 0.78 (0.77, 0.79). Lesion quantification results showed that the total hemorrhage area, maximum hemorrhage area, total exudation area, and maximum exudation area increase with DR severity.ConclusionsSmartEye has a high diagnostic accuracy in DR screening program using non-mydriatic fundus cameras. SmartEye quantitative analysis may be an innovative and promising method of DR diagnosis and grading.

Highlights

  • With the diabetes mellitus (DM) prevalence increasing annually, the human grading of retinal images to evaluate diabetic retinopathy (DR) has posed a substantial burden worldwide

  • The screening program was organized by the Shanghai Eye Disease Prevention & Treatment Center (SEDPTC)

  • All retinal images were collected with a non-mydriatic fundus camera (NW 400, Topcon, Japan) by community healthcare professionals who had been trained by fundus disease experts in SEDPTC

Read more

Summary

Introduction

With the diabetes mellitus (DM) prevalence increasing annually, the human grading of retinal images to evaluate DR has posed a substantial burden worldwide. SmartEye is a recently developed fundus image processing and analysis system with lesion quantification function for DR screening. We reported the diabetic retinopathy (DR) grading results of SmartEye versus ophthalmologists in analyzing images captured with non-mydriatic fundus cameras in community healthcare centers, as well as DR lesion quantitative analysis results on different disease stages. The number of diabetes mellitus (DM) patients worldwide has grown rapidly. The incidence of DR increases with disease duration[4]. In patients with type 2 diabetes with a duration of more than 20 years, the prevalence of DR increases to 60% 5. DR is characterized by retinal microaneurysms, hemorrhages, lipid exudation, vascular closure, and neovascularization[6]

Methods
Results
Discussion
Conclusion