Abstract

Different ad-hoc materials are being used to recover ignitable liquid residues (ILRs) when direct sampling is difficult at a fire scene. Our investigations have shown that these are unable to recover all target compounds specified in the ASTM method for the positive identification of ILRs. A novel adsorbent (limestone and British Fuller’s earth; 10:1w/w) has been developed that is capable of recovering all of the target compounds, applicable to a wide range of ignitable liquids. It does not interfere with the analysis and can easily be used on different surface types. The novel adsorbent was also tested at a cold fire scene where all ILRs were identified. This investigation has proved that ad-hoc materials used by fire investigators are not fit for purpose and could lead to the misinterpretation of evidence in court. Here we propose an inexpensive, innovative and universal adsorbent that could be adopted by fire investigators globally.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.