Abstract

NPL is developing a new clock algorithm to combine measurements from its three active hydrogen masers and caesium fountain clock. The algorithm takes advantage of recent developments, in particular the use of covariance reduction techniques. This algorithm differs from previous Kalman filter clock algorithms in that it has been designed to operate near optimally in the presence of flicker frequency modulation (FFM). The aim of the work is to produce a composite clock that over a wide range of averaging times has near optimal stability. This is achieved by modelling the FFM approximately by a linear combination of Markov noise processes. Each Markov process is included in the Kalman filter and contributes an additional component to the state vector. Both the validity of the model and the effectiveness of adding these additional components to the state vector are examined.The performance of the new algorithm is examined when applied to simulated measurements and also to measurements from NPL's three hydrogen masers. The latter is achieved through comparisons against NPL's caesium fountain clock and against external UTC timescales using two-way time transfer measurements.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.