Abstract

To alleviate signal suppression resulting from nonvolatile positive ion additives, a hydrodynamic flow assisted double junction capillary electrophoresis–mass spectrometry (CE–MS) interface was proposed. The double junction interface which could alleviate the ion suppression due to nonvolatile negative ion additives was modified so that a hydrodynamic flow could be introduced to the interface. Using this setup, the apparent velocity of the ions was determined based on its electrophoretic mobility, electroosmotic flow in the transfer capillary, and hydrodynamic flow introduced by the syringe pump. CE–MS analysis of positively charged triazines was performed to demonstrate the practical value of this approach by using cetyltrimethylammonium ion (CTA+) as an additive. Because the separation column was dynamically coated with CTA+, the EOF was reversed and the separation was performed under counter EOF mode. Under an appropriate hydrodynamic flow, the analytes (triazines) could be propagated toward the MS, whereas the additive (CTA+) ion was retained in the interface. Consequently, the problem of signal suppression by CTA+ was alleviated, and the signals were enhanced more than 20-fold.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.