Abstract

To compare the properties of anodized aluminium oxide layers an easy thickness determination method is wanted. Crevecoeur and De Wit used a method expressing the thickness in terms of peak voltages obtained by forming again after annealing. The aim of the work described here is to relate the value of the peak voltage to the thickness of the layer measured by ellipsometry.On specimens formed in an aqueous solution of b oric acid and ammonium hydroxide the following relation is found between the thickness d (nm) and peak voltage Vp (volt):d = 1.020 Vp + (0.00044 ± 0.00011) Vp2. On specimens formed in a solution of ammonium pentaborate in ethylene glycol the squared Vp term is of a lower value. however when Vp is less than 150 V the above relation holds for layers formed in both electrolytes, the systematic error then being less than 1%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.