Abstract
Chromatography techniques are widely used to separate, identify, and quantify molecules depending on their physicochemical properties. Standard methods range from simple size exclusion to separation based on affinity or ion exchange. Here, we present a method for the direct analysis of carbohydrates in Magnaporthe oryzae using high-performance anion-exchange chromatography (HPAEC) coupled with pulsed amperometric detection (PAD). The combination of HPAEC with PAD provides the highest selectivity and sensitivity with minimal sample preparation and cleanup time. Utilizing our HPAEC-PAD approach, we obtain reliable and highly reproducible determination of carbohydrates produced as osmotic stress response by M. oryzae. Thus, the method described provides a fast, precise, and comprehensive analysis of stress-dependent metabolic adjustments of carbohydrates not only relevant for M. oryzae but also applicable in other systems.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.