Abstract

ObjectiveWe aimed to find and compare the efficacy of ultrasonography (US), technetium-99m methoxyisobutylisonitrile parathyroid scintigraphy (MIBI-S), and single-photon emission computed tomography–computed tomography (SPECT-CT) in detecting the localization of parathyroid adenomas in patients with primary hyperparathyroidism. MethodsIn total, 348 patients were included in this study. Preoperative parathyroid imaging with US, MIBI-S, and SPECT-CT was evaluated and compared with operative findings. The results of the imaging methods were compared with pathology and operation reports. ResultsIn 318 patients (91.3%), one of the imaging methods was able to localize the lesion correctly. US detected the localization of the parathyroid lesions correctly in 268 patients (77%), whereas SPECT-CT and MIBI-S were correct in 254 (73%) and 209 (60%) patients, respectively. There was a statistically significant relationship between the parathyroid hormone (PTH) level and 3 imaging methods’ success rates (P < .05). The PTH cut-off value, which best determined the correct localization, was 152.5 pg/mL for US, 143 pg/mL for MIBI-S, and 143 pg/mL for SPECT-CT. It was observed that the correct localization rate for parathyroid lesions increased with higher PTH levels. ConclusionIn our study population, US was more successful, in most cases, than other imaging methods in localizing parathyroid lesions but SPECT-CT was more accurate in localizing mediastinal lesions. In addition, it was found that preoperative PTH levels affect the accuracy of imaging methods.