Abstract

The americium–beryllium neutron irradiation facility at the National Nuclear Research Institute (NNRI), Ghana, was re-designed with four 20Ci sources using Monte Carlo N-Particle (MCNP) code to investigate the maximum amount of flux that is produced by the combined sources. The results were compared with a single source Am–Be irradiation facility. The main objective was to enable us to harness the maximum amount of flux for the optimization of neutron activation analysis and to enable smaller sample sized samples to be irradiated. Using MCNP for the design construction and neutronic performance calculation, it was realized that the single-source Am–Be design produced a thermal neutron flux of (1.8±0.0007)×106n/cm2s and the four-source Am–Be design produced a thermal neutron flux of (5.4±0.0007)×106n/cm2s which is a factor of 3.5 fold increase compared to the single-source Am–Be design. The criticality effective, keff, of the single-source and the four-source Am–Be designs were found to be 0.00115±0.0008 and 0.00143±0.0008, respectively.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.