Abstract

Objective: To explore a method for digitally designing and fabricating a sequential tooth-sectioning guide that can assist in the extraction of mandibular horizontal impacted third molars, preliminarily evaluate its feasibility and provide a reference for clinical application. Methods: Twenty patients with mandibular low level impacted third molars who visited the Department of General Dentistry, Peking University School and Hospital of Stomatology from March 2021 to January 2022 were selected. Cone-beam CT showed direct contact between the roots and mandibular canal, and full range impressions of the patients' intraoral teeth were taken and optical scans of the dental model were performed. The patients' cone-beam CT data and optical scan data were reconstructed in three dimensions, anatomical structure extraction, registration fusion, and the design of the structure of the guide (including crown-sectioning guide and root-sectioning guide) by Mimics 24.0, Geomagic Wrap 2021, and Magics 21.0 software, and then the titanium guide was three dimension printed, and the guide was tried on the dental model. After confirmation, the guide was used to assist the dentist in the operation. We observed whether the guide was in place, the number of tooth splitting, the matching of tooth splitting with the preoperative design, the operation time, and whether there were any complications. Results: In this study, 20 sectioning guides were successfully printed, all of them were well fitted in the patients' mouth, the average number of section was 3.4 times, the tooth parts was better matched with the preoperative design, and the average operative time of the guides was (29.2±9.8) minutes without complications such as perforation of the bone cortex. Conclusions: The use of sequential sectioning guides to assist in the extraction of mandibular impacted third molars was initially validated to accurately replicate the preoperative sectioning design, and is expected to provide a digital solution to improve surgical precision and ensure safety. Further studies with larger sample sizes are needed to evaluate its accuracy and safety.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.