Abstract

ABSTRACT STARTING with the macroscopic energy and mass balance equations, for three control volumes, (inlets, building, and outlets) equations describing the rate of change of building air temperature and mass flow rates are obtained. Application of the ideal gas equation of state in differential form allows for simplification of the temperature equation. Where possible, all simplifying assumptions are analyzed and justified. All equations, including the standard equation cur-rently in use, are compared numerically indicating a maximum difference of 1.0 °C.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.