Abstract

The durability of membrane electrode assemblies (MEAs) with varying amounts of Pt loading on the cathode of polymer electrolyte membrane fuel cells was investigated using load cycling as an accelerated degradation test (ADT). The single-cell performance of the MEA as determined by the ADT declined by approximately 34, 48, and 78%, when cathode Pt loading in the MEA was reduced to 0.3, 0.2, and 0.1 mg cm −2, respectively. The increase in MEA performance declined at higher cathode Pt loading conditions, and the degradation rate of MEA performance was also diminished. To characterize the electrochemical and structural properties of the MEAs, cyclic voltammograms, electrochemical impedance spectroscopy, X-ray diffraction, X-ray photoelectron spectroscopy, and field-emission scanning electron microscopy were utilized before and after ADT.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.